Publications Office of the EU
DK-Gentofte: Makkinarju u apparat għall-iffiltrar u l-purifikazzjoni tal-gassijiet - Offerti tal-UE
DisplayCustomHeader
Procurement Detail Actions Portlet
OP Portal - Procurement - Details

DK-Gentofte: Makkinarju u apparat għall-iffiltrar u l-purifikazzjoni tal-gassijiet

  • Ippubblikat
    11/10/2011
  • Skadenza
    31/10/2011
  • Aġġudikat
    09/02/2012
  • Illum
    17/08/2026
Status
Aġġudikat
Tip ta’ kuntratt
Supplies
Suġġett għat-Tiġdid
No
Xerrej
Mhux disponibbli
Post tal-prestazzjoni
NUTS code: DK042 Østjylland
Post tax-xerrej
NUTS code: Mhux disponibbli
Settur tan-negozju (CPV ewlieni)
42514000 Makkinarju u apparat għall-iffiltrar u l-purifikazzjoni tal-gassijiet
Stima tal-valur totali tal-kuntratt (eskluża l-VAT)
Mhux disponibbli
Valur totali finali tal-kuntratt (eskluża l-VAT)
Mhux disponibbli
Numru ta’ referenza tal-offerta
2-00381
Deskrizzjoni

The main data of the existing plant are as follows:
1. Flue gas amount: 71,5 kg/s;
2. Gas turbine, model GE LM250PE;
3. Degasification type: Aalborg Ciserv A/S LV24;
4. Current NOx level, both with and without water injection:
a) Without water injection: 1 100 mg/Nm3;
b) With water injection: 680 mg/Nm3.
The new SCR (selective catalytic reduction) plant must comply with the following requirements:
5. The following emissions must as a minimum be observed after installation and commissioning. When determining the level of NOx emission, all NOx must be converted into NO2. In practise, the emission of NO and NOx is measured in ppm. The found values must be added up and the sum must be converted into mg/normal m3 NO2 by the use of the conversion factor for NO2.
— The NOx emission must be kept under 150mg/Nm3 (reference state: 5 % 02, 0 degrees Celsius, 101.3 kPa, dry gas under all operational conditions,
— The ammonia emission must be kept under 12mg/Nm3 (reference state: 5 % 02, 0 degrees Celsius, 101.3 kPa, dry gas under all operational conditions.
The following is included in the supply:
— The existing ammonia storage must be used (24 % dissolution, (NH3) in connection with the installation of the plant,
— Pipe routing, pumps and electrical installation as regards connection to existing ammonia storage,
— Assembly and installation in the time frame (May 2012, June 2012, July 2012),
— Commissioning in the time frame (August 2012). Must be able to comply with emission requirements as of 1.9.2012,
— Scaffolding, insulation in connection with assembly and installation,
— Commissioning,
— Documentation Electronic + 2 x hard copy,
— Operational description (maintenance manuals) electronic + 2 x hard copy,
— C&I concept for control system (Siemens T-3000),
— Third party control and verification of emissions in connection with commissioning,
— KKS numbering of drawings, components, pipe routing and cables.

Metodu ta' Sottomissjoni
Mhux disponibbli
Jistgħu jiġu sottomessi offerti
Submission for all lots
Informazzjoni dwar kuntratt pubbliku, ftehim ta' qafas jew sistema dinamika ta' xiri (DSX)
L-avviż jinvolvi kuntratt pubbliku
Kundizzjonijiet għall-ftuħ tal-offerti (data)
Mhux disponibbli
Post tal-prestazzjoni
Metodu tal-għoti
The most economic tender
Valur stmat
Mhux disponibbli
Valur kuntrattwali finali
Mhux disponibbli
Għoti tal-kuntratt
Isem uffiċjali: Industrivarme
Indirizz postali: Landholmvej 12
Belt: Storvorde
Kodiċi postali: 9280
Pajjiż: DNK
Informazzjoni minn qabel
Kuntratt
Għoti
Footnote - legal notice

Dan il-kontenut ippubblikat f’din il-paġna hu maħsub purament bħala servizz addizzjonali u m’għandu ebda effett legali. L-istituzzjonijiet tal-Unjoni ma jassumu ebda responsabbiltà għall-kontenut tiegħu. Il-verżjonijiet uffiċjali tal-avviżi rilevanti dwar l-offerti huma dawk ippubblikati fis-Suppliment tal-Ġurnal Uffiċjali tal-Unjoni Ewropea u disponibbli fit-TED. Dawk it-testi uffiċjali huma aċċessibbli direttament permezz tal-links inkorporati f’din il-paġna. Għal aktar informazzjoni jekk jogħġbok ara l-Avviż ta’ Spjegabbiltà u Responsabbiltà tal-Akkwist Pubbliku.