Announced25/04/2025
-
Today24/05/2025
-
Estimated published02/06/2025
Utilities
- indicates text translated automatically in your browsing language
Iceberg hall - Heating installation Text automatically translated in your browsing language Automatically translated
- approx. 170m underground pipe in duo design, DN25 - 75 - 1 pc. pellet boiler 150kW with pellet storage as room discharge 40m3 - 1 pc. heating distributor incl. fittings and pumps - 1 pc. buffer tank 5.000ltr, standing, incl. insulation - approx. 25m exhaust pipe, stainless steel insulated, DN200, double-walled - approx. 180m heating pipe, stainless steel DN15 - 65, incl. MiWo insulation - approx. 1.000m2 underfloor heating, incl. insulation panel, VA 10 - 30cm, - approx. 7 underfloor heating distributors - 3 pc. fresh water station approx. 100kW - 1 pc. fresh water station approx. 35kW Text automatically translated in your browsing language Automatically translated
https://www.vergabe24.de/
https://www.vergabe24.de/
This content published on this page is meant purely as an additional service and has no legal effect. The Union's institutions do not assume any liability for its contents. The official versions of the relevant tendering notices are those published in the Supplement of Official Journal of the European Union and available in TED. Those official texts are directly accessible through the links embedded in this page. For more information please see Public Procurement Explainability and Liability notice.