-
Published12/08/2026
-
Today06/09/2026
-
Deadline16/09/2026
-
Opening of tenders16/09/2026
Utilities
- indicates text translated automatically in your browsing language
Construction of a gymnasium of the Reformed Lyceum of Gödöllő
Contractor's task is 2100 Gödöllő, Szabadság tér 9., hrsz. Construction of gymnasium C on the property under 401. Construction organisation: The construction procession and the service of the project will take place from Kossuth u 5-7 33,50m x 30m, floor+floor+roof area Built-in floor area: 100997 m2 Useful floor area:1539.24 m2 Foundation: Well bases with head beams prefabricated reinforced concrete pillars and beams, 30cm thick Silka HML 300 NF+GT limestone sand with brick frame filler masonry Roofing structure 5.0 cm concrete pavement foundations (40x40x5 cm) 1 rtg 1.8 mm thickness, mechanically fixed, UV and weather resistant (MSZ EN 13956), polyester reinforced, multilayer, special quality PVC rainwater insulation (e.g.: SikaPlan G-18), loosely laid, in 5 cm interlaces, at least 3 cm hot air welded, surface-continued (white - RAL 9016) 1 rtg. Plastic veil separation layer with a surface weight of 120 g/m2, loosely laid with 15 cm overlaps (S-Glass Fleece 120) 8 cm inhomogeneous rock wool thermal insulation sheet (Rockwool Durock) 18 cm homogeneous rock wool thermal insulation sheet (Rockwool Roofrock 60) 1 rtg. 0.6 mm vtg. self-adhesive composite aluminium foil, protection against humidity (e.g. RW Bautech Alutrix 600) 15.3 cm T153 galvanised steel trapezoidal slab (according to the structural plan), Rockwool SF 50 acoustic rib filler, built on a prefabricated reinforced concrete beam statically dimensioned, 5 cm double-layered composite (stone wool core + /Heraklith/freeze wool cover) sheet acoustic ceiling covering (Wallet A2 037/ Housingsings: Graboplast StrongAir sports parquet, EN 13849 multilayer parquet, 5,2 mm thick hardwood colour layer, changing rooms, corridor: cold cladding Exterior wall cladding: double stator 0.7 mm thick, coil coating coated aluminium sheet covering (e.g. Prefalz system) pitch: 600-150 mm, - RAL 7005 - light grey colour, laminated with 15 cm black glass veil, fully hydrophobized rock wool with thermal insulation Matrix premium facade cladding Mechanical engineering: Heating: In changing rooms: 2 pcs Baleria (20) outdoor,WHAT indoor heat pump cooling heater, split system, air-water heat pump (inverter) 9kW each, underfloor heating Gymnasium: With 2 Roof-top compact air handling units, each with a delivered volume flow rate: V=6000 m3/h, Dp st=200 Pa, with heat recovery Connect control automation to the control of the built D building Detailed technical documentation is included in the technical specifications, procurement documentation, draft contract and unpriced budget that are part of the procurement documents. Sports Technology Option: Ball catcher net 3,00 x 4,80 6 pcs Metalobox double-sided backrest dressing bench 1600x2000x740 16 pcs Metalobox single-sided backrest dressing bench 1600x1500x360 12 pcs Metalobox single-sided backrest dressing bench 1600x2000x360 4 pcs Metalobox dressing bench 450x1500x3302 pcs Metalobox dressing bench 450x1000x330 2 pcs Metalobox locker 800x1200x500 2 pcs Metalobox locker 800x900x500 2 pcs Metalobox locker 800x600x500 2 pcs Building automation option: Preparation of external temperature sensor | 1 pcs • water temperature sensor, 24 pcs • pressure switch 3 pcs • Submersible/contact boundary thermostat 2 pcs DDC POSITIONS • EA1 Thermocoupler installation 1 pcs BUILDING SURVEILLANCE CENTER • building management software package 1 pcs • monitoring PC 1 klt UV standing hose in existing outdoor cable support structure, installation of complete 30 fm indoor cable support structure, RKS100*60mm perforated metal cable tray, complete with support structure 20 fm MÜII protective hose with pop-up clamps, for field devices complete 150 fm YSLY-Jz 3x1,5 mm2 cable laying complete with complete 700 fm J-Y(St)Y 2x2x0,8 mm2 cable laying complete with complete installation of complete 1000 fm LimYC 3x2 mm cable line, installation of complete electrical pipes in both sides of pipes
https://ekr.gov.hu/eljarastar/eljaras/EKR001115262026
https://ekr.gov.hu/eljarastar/eljaras/EKR001115262026
Type: quality
Description: M.2/1 alkalmassági követelményben meghatározott szakember esetén az alkalmassági követelményben előírton felüli szakmai tapasztalat (min.0-max.36 hónap)
Weight (percentage, exact): 10
Criterion:
Type: quality
Description: M.2/2 alkalmassági követelményben meghatározott szakember esetén az alkalmassági követelményben előírton felüli szakmai tapasztalat (min.0-max.36 hónap)
Weight (percentage, exact): 10
Criterion:
Type: quality
Description: M.2/3 alkalmassági követelményben meghatározott szakember esetén az alkalmassági követelményben előírton felüli szakmai tapasztalat (min.0-max.36 hónap)
Weight (percentage, exact): 10
Criterion:
Type: price
Description: teljes - opciók értékét is tartalmazó - nettó vállalkozói díj
Weight (percentage, exact): 70
This content published on this page is meant purely as an additional service and has no legal effect. The Union's institutions do not assume any liability for its contents. The official versions of the relevant tendering notices are those published in the Supplement of Official Journal of the European Union and available in TED. Those official texts are directly accessible through the links embedded in this page. For more information please see Public Procurement Explainability and Liability notice.