-
Published11/06/2021
-
Deadline13/08/2021
-
Awarded09/12/2021
-
Today14/05/2026
Utilities
- indicates text translated automatically in your browsing language
Hungary-Budapest: Construction work
435/2015. (XII. Among the tasks of the Contracting Authority (AK) the Environmental and Energy Efficiency Operational Programme of the 2014-2020 prog. (hereinafter: The implementation of public procurement procedures necessary for the implementation of priority projects aimed at implementing the building energy investment of a public sector body financed by KEHOP. The subject of this public procurement procedure is the implementation of the construction works of the project KEHOP-5.2.2/16-2017-00113 entitled ‘Building energy investments in disaster protection properties’, as detailed in the procurement documents to be issued to tenderers. The project is the 4.Záhony Disaster Management Őrs Szabolcs-Szatmár-Bereg County 598/13 HRSZ; 4625 Záhony, Baross Gábor út 8th building (i). The building(s) were built at the same technological standard as the building(s), but the boundary structures and the obsolete, sometimes poorly closed windows do not meet the requirements of today’s thermal engineering and building structure, so the building(s) operate with significant heat loss. The building energy investment includes the subsequent thermal insulation of external boundary wall and slab structures, the modernisation of heating and cooling systems, as well as the installation of a photovoltaic system producing electricity in the current 7/2006. (IV.24.) by complying with the requirements of the Decree of the Minister for National Development, aiming to save the energy costs of operation as much as possible. Architectural renovation works aimed at the energetic modernisation of the building(s) shall concern the external boundary structures of the building(s). The facade walls of the building(s), the plinths and the flat roofs must also be thermally insulated. In connection with the thermal insulation of flat roofs, it is necessary to renovate the insulation against rainwater on flat roofs everywhere. It is necessary to replace the facade doors and windows that do not meet today’s energy requirements. It is also necessary to establish the modernisation of the heating network and the regulation of the heating system for certain buildings. A heat-recovery ventilation system to be developed for some buildings. It should also be installed in a solar system. Activities eligible for KEHOP support: Main planned quantities: Replacement of facade doors and windows with related works Replacement of facade doors and windows 314.5 m² Roof thermal insulation with subsequent thermal insulation of the roof 680.5 m² Heat and waterproofing of the roof with related works Related works of retrofitting of facades EPS and peg XPS thermal insulation system with OTSZ fire retardation strips 1 522.7 m² of which – EPS: 1 455.4 m² (including rock wool bands according to the NSZ) – XPS: 67.3 m² Thermostatic radiator valve replacement with the related works of building mechanical heating system with related works 26 pcs Installation of heat recovery ventilation system with related works 26 pcs Development of renewable energy consumption with Solar Power System Performance: 22,68kWp (84pcs 270Wp solar panel) Ineligible activities for the KEHOP aid: The installation of the shutter/shadow system for facade windows (windows only) is for informational purposes 60 pcs The quantities specified in this section are for informational purposes, further information is provided in the Public Procurement Documents and technical specifications. AK is 321/2015. Pursuant to Section 46(3) of Government Decree (X. 30.) of Government Decree (X. 30.) of Government Decree (X. 30.) it states that references to items, processes, activities, persons, patents or trademarks of a make, origin, type, as defined in the invitation to tender and in the procurement documents are only made in order to clearly determine the nature of the subject matter, and the designation is to be understood as ‘or equivalent’. Proof of equivalence shall be the responsibility of the tenderer (AT). The plans issued, together with the related technical specifications, other documents and the budgets sent, shall be read together.
Official name: BMSK Sport Közhasznú Nonprofit Kft.
National registration number: 23007266242
Postal address: Istvánmezei út 1–3.
Town: Budapest
NUTS code: HU110
Postal code: 1146
Country: HUN
Contact person: Hideghéti- Szemerédi Anna Zsófia
Main address: https://www.bmsk.hu/bmsk-nonprofit-kft/
Electronic via:
https://ekr.gov.hu/portal/kozbeszerzes/eljarasok/EKR000362782021/reszletek
Belügyminisztérium Országos Katasztrófavédelmi Főigazgatóság
Postal address: Erdőalja Utca 39.
Town: Nyíregyháza
Postal code: 4431
Country: HUN
This content published on this page is meant purely as an additional service and has no legal effect. The Union's institutions do not assume any liability for its contents. The official versions of the relevant tendering notices are those published in the Supplement of Official Journal of the European Union and available in TED. Those official texts are directly accessible through the links embedded in this page. For more information please see Public Procurement Explainability and Liability notice.