Publications Office of the EU
The device for accelerated aging tests and resistance of color to light with xenon lamps and a set of optical filters. - Public Procurement procedure view
DisplayCustomHeader
Procurement Detail Actions Portlet
OP Portal - Procurement - Details

This page contains content generated automatically to improve findability and accessibility

- indicates text translated automatically in your browsing language

The device for accelerated aging tests and resistance of color to light with xenon lamps and a set of optical filters. Text automatically translated in your browsing language Automatically translated

  • Published
    22/11/2024
  • Today
    02/12/2024
  • Deadline
    06/12/2024
  • Opening of tenders
    06/12/2024
Status
Published
Type of contract
Supplies
Subject for Renewal
No
Buyer
Sieć Badawcza ŁUKASIEWICZ - Łódzki Instytut Technologiczny
Place of performance
NUTS code: Multiple place of performance
Location of buyer
NUTS code: PL711 Miasto Łódź
Business sector (Main CPV)
38500000 Checking and testing apparatus
Total estimated contract value (excluding VAT)
Not available
Total final contract value (excluding VAT)
Not available
Tender reference number
FO-Z/ŁIT/40/2024
Description

4.1. The subject of the order is the delivery of the Camera for accelerated aging tests and resistance of color to light with xenon lamps and a set of optical filters. The device should meet the requirements set out in Annex 1a to the SWZ – Description of the subject-matter of the contract, hereinafter referred to as: ‘equipment’. In addition, it should be provided with a calibration certificate (calibration laboratories meeting the requirements of the document of the Polish Centre for Accreditation – DA-06 ‘Policy on measurement consistency of measurement results’) for an irradiance sensor, a black-plate thermometer (BPT) or a black standard thermometer (BST), and for humidity and temperature sensors. The offered equipment must be brand new and unused, come from the current production (year of production: 2023 or 2024), meet the required standards, have appropriate approvals, certificates, be allowed to be sold and used in the Republic of Poland. The cost of transport, including insurance, shall be borne by the Contractor. The Contractor is obliged to attach to the delivered equipment all operating instructions and service instructions in Polish or English (if any). Submitting an offer for equipment that does not meet all the parameters or has parameters worse than those recorded in Annex 1a to the SWZ will result in the rejection of the offer. 4.2. The scope of the contract also includes the delivery of equipment to the seat of the Ordering Party along with bringing, installing and optimizing the device for the needs of the Ordering Party, the first start-up and configuration of the software and application and usage training in the field of camera and software operation. As part of the price, the Contractor will conduct the necessary (stationary) training of 6 users (employees) of the Ordering Party on the operation of the delivered device to the extent necessary to properly operate them. 4.3. The Contractor shall ensure: a) free authorized warranty service of equipment in Poland b) spare parts (including lamps) for at least 10 years from the date of completion of production c) free delivery and replacement of necessary parts during the warranty period d) warranty period of at least 12 months 2. Min. technical requirements/parameters: a) Dimensions: max (width, depth, height) 130 x 120 x 190 cm (b) radiation source in the form of xenon lamps and color temperature between 5500 K and 6500 K, lamps equipped with automatic or manual power adjustment, (c) automatic control of radiation intensity, radiation control allowing radiation control for the spectral range 300-400 nm (d) daylight optical filter system for aging tests with simulation of natural solar radiation outdoors, filter placed between the light source and the tested samples, filters should ensure that the ultraviolet range of radiation is permanently reduced, glass characterized by 0% transmission in the range of 290 nm to 300 nm and increase to at least 90% in the range of 380 nm to 750 nm (e) set of optical filters used for aging tests for the simulation of natural solar radiation indoors, so-called. "behind the window pane" specially designed for high temperature tests in accordance with the requirements of PN-EN ISO 105-B06 for materials used inside motor vehicles f) filters complying with the requirements of standards: PN-EN ISO 4892-2, PN-EN ISO 16474-2, g) temperature sensor – black plate thermometer (BPT) or black standard thermometer (BST), mounted at the level of test samples, the irradiation device should be designed in such a way that the temperature of the BPT or BST sensor, located anywhere in the irradiation area of the sample, is within ±5oC of the required temperature, the irradiation device should be designed in such a way that the control of the temperature of the black standard is within ±3oC of the required temperature h) the temperature control range of the black standard from 30oC to 115oC (the above condition will be met and recognized when the temperature control range of the black standard is within the above range) i) the total available area for samples min. 1800 cm2 j) the place for fixing samples k) programming and automatic adjustment of four parameters of the ageing test: natężenia promieniowania, temp. czarnego wzorca BST lub BPT, temperatury powietrza i wilgotności względnej powietrza l) zakres regulacji temperatury powietrza w komorze od 30 do 65 °C dla cyklu z naświetlaniem (powyższy warunek zostanie spełniony i uznany, gdy zakres regulacji temperatury powietrza będzie zawierał się w powyższym zakresie, lub będzie szerszy niż powyższy zakres) m) zakres regulacji wilgotności względnej powietrza w komorze roboczej od 20 %RH do 95 %RH dla cyklu z naświetlaniem, (powyższy warunek zostanie spełniony i uznany, gdy zakres regulacji wilgotności będzie zawierał się w powyższym zakresie lub będzie szerszy niż powyższy zakres) n) programowanie okresu trwania testu poprzez określenie czasu lub dawki promieniowania w MJ/m2 o) programowany system okresowego zraszania (nadeszczania) próbek, możliwość pracy z zamkniętym obiegiem lub z otwartym obiegiem wody (jeśli otwarty obieg wody – demineralizator z zestawem filtrów ze zbiornikiem na wodę min. 30 L) p) - dedykowane uchwyty i maski do przesłaniania, dedykowane dla PN-EN ISO 105-B02:2014-11, PN-EN ISO 105-B04:1999, PN-EN ISO 105-B06 oraz z tworzyw sztucznych wg PN-EN ISO 4892-2, powłok z farb i lakierów wg PN-EN ISO 16474-2. q) możliwość wpisania własnych programów użytkownika minimum 5 programów r) urządzenie powinno być zaprojektowane w taki sposób, aby zapewniało, że wahania natężenia promieniowania światła na powierzchni, na której umieszczone są próbki robocze i wzorce, nie powinny przekraczać ±10% wartości średniej. 3. The device should be supplied with a calibration certificate. Text automatically translated in your browsing language Automatically translated

Submission Method
Electronic via:
https://lit.eb2b.com.pl
Tenders may be submitted
Electronic submission: required
https://lit.eb2b.com.pl
Information about a public contract, a framework agreement or a dynamic purchasing system (DPS)
Not available
Conditions for opening tenders (date)
06/12/2024 11:15
Place of performance
Award method
Criterion:
Type: price
Description: Cena oferty brutto
Weight (percentage, exact): 90
Criterion:
Type: quality
Description: Wydłużenie okresu gwarancji
Weight (percentage, exact): 10
Estimated value
Not available
Final contracted value
Not available
Award of contract
Not available
Prior information
Contract
Award
Footnote - legal notice

This content published on this page is meant purely as an additional service and has no legal effect. The Union's institutions do not assume any liability for its contents. The official versions of the relevant tendering notices are those published in the Supplement of Official Journal of the European Union and available in TED. Those official texts are directly accessible through the links embedded in this page. For more information please see Public Procurement Explainability and Liability notice.